C00678 | l_gainoffsetphip 1-2: parameter, C00679 | l_muldiv_2: parameter, C00680 | l_compare_1: fct – Lenze 8400 TopLine User Manual
Page 1045: C00681 | l_compare_1: hysteresis, C00680, C00681, 17 parameter reference
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1045
17
Parameter reference
17.2
Parameter list | C00678
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00678
C00679
C00680
C00681
Parameter | Name:
C00678 | L_GainOffsetPhiP 1-2: Parameter
Data type: INTEGER_32
Index: 23897
d
= 5D59
h
Gain and offset
Setting range
(min. value | unit | max. value)
-2147483647
2147483647
Subcodes
Lenze setting
Info
C00678/1
65536
: Gain
C00678/2
0
: Offset
C00678/3
65536
: Gain
C00678/4
0
: Offset
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00679 | L_MulDiv_2: Parameter
Data type: INTEGER_16
Index: 23896
d
= 5D58
h
FB: Numerator and denominator
Setting range
(min. value | unit | max. value)
-32767
32767
Subcodes
Lenze setting
Info
C00679/1
0
: Numerator
C00679/2
10000
: Denominator
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00680 | L_Compare_1: Fct.
Data type: UNSIGNED_8
Index: 23895
d
= 5D57
h
FB: Comparison operation
• If the statement of the selected comparison operation is true, the binary bOut output will be set to TRUE.
Selection list
(Lenze setting printed in bold)
1 In1 = In2
2 In1 > In2
3 In1 < In2
4 |In1| = |In2|
5 |In1| > |In2|
6 |In1| < |In2|
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00681 | L_Compare_1: Hysteresis
Data type: INTEGER_16
Index: 23894
d
= 5D56
h
FB: Hysteresis for the comparison function selected in
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
100.00 0.50 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100