7 action type "switching, 7 action type "switching" 7, L_sequencer_1: "switching" action – Lenze 8400 TopLine User Manual
Page 1657: Switching, 19 function library, 2 x x x
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1657
19
Function library
19.1
Function blocks
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
19.1.158.7 Action type "switching"
For switching digital output signals, 16 actions of "switching" type are available. Every action can set
two selectable bits of the wDigitalOutputs output signal to "0" or "1", independent of each other.
Action call (entry in the sequence table)
with action number xxx = 001 ... 016
Parameter
The available actions 1 ... 16 are represented via the subcodes 1 ... 16.
Parameter
Possible settings
Info
Switching act. n: Output switching A
• Selection of the sequencer output
which is to be set to the polarity
0 Deactivated
1 Sequencer output 1
(Bit 0 of wDigitalOutputs)
2 Sequencer output 2
(Bit 1 of wDigitalOutputs)
... ...
16 Sequencer output 16
(Bit 15 of wDigitalOutputs)
Switching act. n: Pol. switching A
• State to which the sequencer
output selected in
is to
be set.
0 Set output bit to "0"
1 Set output bit to "1"
Switching act. n: Output switching B
• Selection of the sequencer output
which is to be set to the polarity
0 Deactivated
1 Sequencer output 1
(Bit 0 of wDigitalOutputs)
2 Sequencer output 2
(Bit 1 of wDigitalOutputs)
... ...
16 Sequencer output 16
(Bit 15 of wDigitalOutputs)
Switching act. n: Pol. switching B
• State to which the sequencer
output selected in
is to
be set.
0 Set output bit to "0"
1 Set output bit to "1"
2 x x x