C00444 | dox: level, C00445 | freqinxx_nout_v, C00445/1 – Lenze 8400 TopLine User Manual
Page 981: C00445/2, C00444/1, C00444/2, 17 parameter reference
![background image](/manuals/566308/981/background.png)
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
981
17
Parameter reference
17.2
Parameter list | C00444
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00444
C00445
Parameter | Name:
C00444 | DOx: Level
Data type: UNSIGNED_16
Index: 24131
d
= 5E43
h
Bit coded display of the level of the digital outputs
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Relay
Bit set = HIGH level
Bit 1 DO1
Bit 2 DO2
Bit 3 DO3
Bit 4 High current
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Subcodes
Info
C00444/1
DOx: Input level
C00444/2
DOx: Terminal level
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00445 | FreqInxx_nOut_v
Data type: INTEGER_16
Index: 24130
d
= 5E42
h
Display of the frequency input signals which are fed into the application.
Using DI1(6) and DI2(7) as frequency inputs
Display range
(min. value | unit | max. value)
-32767
Incr/ms
32767
Subcodes
Info
C00445/1
FreqIn12_nOut_v
C00445/2
FreqIn67_nOut_v
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1