17
Parameter reference
17.2
Parameter list | C00760
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00760
Parameter | Name:
C00760 | LA_SwitchPos: Analog connection list
Data type: UNSIGNED_16
Index: 23815
d
= 5D07
h
Connection parameters for "Switch-off positioning" application: 16-bi inputs
• Selection of the 16 bit output signals to be connected to the 16 bit input signals
• The selection list contains all 16 bit output signals which can be assigned to the 16 bit inputs displayed by the
subcodes.
Selection list
See
selection list - analog signals
Subcodes
Lenze setting
Info
C00760/1
0: Not connected
: wCANDriveControl
Input for control word from CAN to device control
C00760/2
0: Not connected
: wMCIDriveControl
Input for control word from communication interface to
device control
C00760/3
0: Not connected
: nVoltageAdd_a
Input for additive voltage impression
C00760/4
0: Not connected
Input for additional setpoint for motor voltage at speed
= 0
C00760/5
0: Not connected
: nPWMAngleOffset
Input for additional offset for the electrical angle of
rotation
C00760/6
0: Not connected
: nTorqueMotLim_a
Input for maximum torque in motor mode
C00760/7
0: Not connected
: nTorqueGenLim_a
Input for maximum torque in generator mode
C00760/8
0: Not connected
: nMainSetValue_a
Input for main speed setpoint
C00760/9
0: Not connected
: nAuxSetValue_a
Input for additional speed setpoint
C00760/10
0: Not connected
: nGPAnalogSwitchIn1_a
Input for analog switch - analog signal 1
C00760/11
0: Not connected
: nGPAnalogSwitchIn2_a
Input for analog switch - analog signal 2
C00760/12
0: Not connected
: nGPArithmetikIn1_a
Input for arithmetic function - analog signal 1
C00760/13
0: Not connected
: nGPArithmetikIn2_a
Input for arithmetic function - analog signal 2
C00760/14
0: Not connected
: nGPMulDivIn_a
Input for analog signal for multiplication/division
C00760/15
0: Not connected
Input for comparison operation - analog signal 1
C00760/16
0: Not connected
Input for comparison operation - analog signal 2
C00760/17
0: Not connected
: wSMCtrl
Interface to the optional safety system
C00760/18
0: Not connected
Reserved
C00760/19
0: Not connected
Reserved
C00760/20
0: Not connected
Reserved
C00760/21
0: Not connected
Reserved