C02244 | ls_writeparamlist: auto-dcb: hold time, C02241/1, C02241/2 – Lenze 8400 TopLine User Manual
Page 1244: C02241/3, C02241/4, C02242/1, C02242/2, C02242/3, C02242/4, C02244/1
17
Parameter reference
17.2
Parameter list | C02241
1244
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02241
C02242
C02244
Parameter | Name:
C02241 | LS_WriteParamList: Motor magnetizing inductance
Data type: UNSIGNED_16
Index: 22334
d
= 573E
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.0
mH
6500.0
Subcodes
Lenze setting
Info
C02241/1
81.0 mH
: c92_val1
C02241/2
81.0 mH
: c92_val2
C02241/3
81.0 mH
: c92_val3
C02241/4
81.0 mH
: c92_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C02242 | LS_WriteParamList: Motor magnetising current
Data type: UNSIGNED_16
Index: 22333
d
= 573D
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.00
A
320.00
Subcodes
Lenze setting
Info
C02242/1
8.50 A
: c95_val1
C02242/2
8.50 A
: c95_val2
C02242/3
8.50 A
: c95_val3
C02242/4
8.50 A
: c95_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C02244 | LS_WriteParamList: Auto-DCB: Hold time
Data type: UNSIGNED_32
Index: 22331
d
= 573B
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.000
s
999.000
Subcodes
Lenze setting
Info
C02244/1
0.500 s
: c106_val1
C02244/2
0.500 s
: c106_val2
C02244/3
0.500 s
: c106_val3
C02244/4
0.500 s
: c106_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000