C00937 | field-oriented motor currents, C00939 | ultimate motor current, C00940 | l_convw numerator – Lenze 8400 TopLine User Manual
Page 1125: C00939, This ensu, C00938, C00937/1, C000937/1, 17 parameter reference
![background image](/manuals/566308/1125/background.png)
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1125
17
Parameter reference
17.2
Parameter list | C00937
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00937
C00938
C00939
C00940
Parameter | Name:
C00937 | Field-oriented motor currents
Data type: INTEGER_16
Index: 23638
d
= 5C56
h
From version 02.00.00
Field weakening for synchronous motors
Display range
(min. value | unit | max. value)
-320.00
A
320.00
Subcodes
Info
C00937/1
Field-producing current
C00937/2
Torque-producing current
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00938 | PSM: Maximum motor current field weakening
Data type: UNSIGNED_16
Index: 23637
d
= 5C55
h
From version 02.00.00
Field weakening for synchronous motors
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
500.00 30.00 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00939 | Ultimate motor current
Data type: UNSIGNED_16
Index: 23636
d
= 5C54
h
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
A
3000.0 3000.0 A
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C00940 | L_ConvW numerator
Data type: INTEGER_16
Index: 23635
d
= 5C53
h
Setting range
(min. value | unit | max. value)
-32767
32767
Subcodes
Lenze setting
Info
C00940/1
1
: Numerator
C00940/2
1
: Numerator
C00940/3
1
: Numerator
C00940/4
1
: Numerator
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1