C01252 | mck: s-ramp times stop, C01294 | mode: position calculation, C01295 | l_mckstateinterface_1: pos. selection – Lenze 8400 TopLine User Manual
Page 1196: Selected in, C01295, In [units, In [increm, C01252/1, 17 parameter reference
17
Parameter reference
17.2
Parameter list | C01252
1196
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01252
C01294
C01295
Parameter | Name:
C01252 | MCK: S-ramp times stop
Data type: UNSIGNED_16
Index: 23323
d
= 5B1B
h
S-ramp times for stop
• Setting "0 s" ≡ no rounding
Setting range
(min. value | unit | max. value)
0.000
s
10.000
Subcodes
Lenze setting
Info
C01252/1
0.000 s
MCK: Stop: S-ramp time
• S-ramp time for setpoint speed ramp-down to
standstill.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C01294 | Mode: Position calculation
Data type: UNSIGNED_8
Index: 23281
d
= 5AF1
h
From version 12.00.00
Selection of the conversion mode
Selection list
0 dnOut_p=ConvWordsToDInt(HW_L
W)
1 16 bits: LW=+/-32767
2 16 bits: HW=+/-; LW=0..65535
3 32Bit: HW_LW=+/-214748.3647
Subcodes
Lenze setting
Info
C01294/1
0:
dnOut_p=ConvWordsToDInt(HW_L
W)
: PosCalcMode
C01294/2
0:
dnOut_p=ConvWordsToDInt(HW_L
W)
: PosCalcMode
C01294/3
0:
dnOut_p=ConvWordsToDInt(HW_L
W)
: PosCalcMode
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01295 | L_MCKStateInterface_1: Pos. selection
Data type: UNSIGNED_8
Index: 23280
d
= 5AF0
h
Selection of the position to be provided at the dnPosOut_p output of the FB
Selection list
(Lenze setting printed in bold)
0 dnPosIn_p
1 Current feed
2 dnSetPos_p
3 dnActPos_p
4 dnDeltaPos_p
5 dnTargetPos_p
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1