6
Encoder/feedback system
6.3
Multi-Encoder (X8)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.3.5.1
Scaling of position value
If you click the Scaling of position value... button in the parameterisation dialog for the
encoder/feedback system in the category "Multi-Encoder (X8), you get to the respective
parameterisation dialog:
Short overview of the relevant parameters:
6.3.5.2
Setting of a static position offset
If, for example, the encoder cannot be mounted mechanically in order that the supplied position
matches the mechanics or if for other reasons, a static position offset is required, this value can be
set in
.
Parameter
Info
Lenze setting
Value Unit
LS_MultiEncoder: Solid measure
• Setting of rotative or linear encoders.
Note: The selection "rotative" or "linear" only has an
impact if the encoder has not been detected
automatically or the encoder data definitely are to be
taken from the codes (bit 0 in
The "unipolar" or "bipolar" selection definitely has an
impact.
0: rotatively unipolar
Settings for linear SinCos absolute value encoder with HIPERFACE® protocol
LS_MultiEncoder: Difference - traverse path
• Specification of the traverse path while passing
through the step number of the Hiperface track
given in
• Setting is relevant for parameter channel.
1 units
LS_MultiEncoder: Difference - encoder path
• Step number of the Hiperface track.
• Setting is relevant for parameter channel.
1 Steps
LS_MultiEncoder: Traverse path - encoder increment
• Specification of the traverse path while passing
through the number of increments of the SinCos
.
• Setting is relevant for process data channel
(incremental SinCos track).
1 units
Further settings
MCK: Feed constant
360.0000 units/rev.