C00368 | can sync tx identifier, C00369 | can sync transmission cycle time, C00368 – Lenze 8400 TopLine User Manual
Page 963: C00369, 17 parameter reference
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
963
17
Parameter reference
17.2
Parameter list | C00368
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00368
C00369
Parameter | Name:
C00368 | CAN SYNC Tx identifier
Data type: UNSIGNED_16
Index: 24207
d
= 5E8F
h
Identifier by means of which the sync master is to transmit sync telegrams.
• Mapping of the CANopen object
(see DS301 V4.02).
Setting range
(min. hex value | max. hex value)
Lenze setting
0x0000
0xFFFF 0x0080 (decimal: 128)
Value is bit-coded: ( = bit set)
Bit 0 COBID Bit0
Bit 1 COBID Bit1
Bit 2 COBID Bit2
Bit 3 COBID Bit3
Bit 4 COBID Bit4
Bit 5 COBID Bit5
Bit 6 COBID Bit6
Bit 7 COBID Bit7
Bit 8 COBID Bit8
Bit 9 COBID Bit9
Bit 10 COBID Bit10
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15 Sync-transmit off
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00369 | CAN sync transmission cycle time
Data type: UNSIGNED_16
Index: 24206
d
= 5E8E
h
Cycle during which the sync master is to transmit sync telegrams.
• If "0 ms" is set (Lenze setting), no sync telegrams are generated.
• Mapping of the CANopen object
(see DS301 V4.02).
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
65000 0 ms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1