C00343 | lp_canin decoupling value, C00343/1, C00343/2 – Lenze 8400 TopLine User Manual
Page 954: C00343/5, C00343/9, C00343/13, 17 parameter reference
![background image](/manuals/566308/954/background.png)
17
Parameter reference
17.2
Parameter list | C00343
954
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00343
Parameter | Name:
C00343 | LP_CanIn decoupling value
Data type: UNSIGNED_16
Index: 24232
d
= 5EA8
h
Definition of the value the process data words are to have in the decoupled state.
Configuring exception handling of the CAN PDOs
Setting range
(min. value | unit | max. value)
0
65535
Subcodes
Lenze setting
Info
C00343/1
0
:wCtrl DiscVal
C00343/2
0
:wIn2 DiscVal
C00343/3
0
:wIn3 DiscVal
C00343/4
0
:wIn4 DiscVal
C00343/5
0
:wIn1 DiscVal
C00343/6
0
:wIn2 DiscVal
C00343/7
0
:wIn3 DiscVal
C00343/8
0
:wIn4 DiscVal
C00343/9
0
:wIn1 DiscVal
C00343/10
0
:wIn2 DiscVal
C00343/11
0
:wIn3 DiscVal
C00343/12
0
:wIn4 DiscVal
C00343/13
0
:wIn1 DiscVal
•
From version 15.00.00
C00343/14
0
:wIn2 DiscVal
•
From version 15.00.00
C00343/15
0
:wIn3 DiscVal
•
From version 15.00.00
C00343/16
0
:wIn4 DiscVal
•
From version 15.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1