C00130 | rated power - brake resistor, C00131 | rated heat amount of brake resist, C00133 | brake resistor utilisation – Lenze 8400 TopLine User Manual
Page 914: C00134 | l_nset_1: ramp smoothing, C00133, C00130, C00131, C00134, 17 parameter reference
![background image](/manuals/566308/914/background.png)
17
Parameter reference
17.2
Parameter list | C00130
914
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00130
C00131
C00133
C00134
Parameter | Name:
C00130 | Rated power - brake resistor
Data type: UNSIGNED_16
Index: 24445
d
= 5F7D
h
Rated power of the connected brake resistor
• The value to be entered can be obtained from the nameplate of the brake resistor.
Setting range
(min. value | unit | max. value)
Lenze setting
0
W
65535 100 W
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00131 | Rated heat amount of brake resist.
Data type: UNSIGNED_16
Index: 24444
d
= 5F7C
h
Thermal capacity of the connected brake resistor
• The value to be entered can be obtained from the nameplate of the brake resistor.
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
kWs
6553.5 10.0 kWs
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C00133 | Brake resistor utilisation
Data type: UNSIGNED_16
Index: 24442
d
= 5F7A
h
Display of the utilisation of the connected brake resistor
Display range
(min. value | unit | max. value)
0
%
65535
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00134 | L_NSet_1: Ramp smoothing
Data type: UNSIGNED_8
Index: 24441
d
= 5F79
h
FB: Configuration of the ramp rounding for the main setpoint
Selection list
(Lenze setting printed in bold)
Info
0 Off
Ramp rounding deactivated
1 PT1 behaviour
Ramp rounding with PT1 behaviour
• The corresponding S-ramp time must be set in
.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1