C02589
Bit 6 SyncRampe L_NSet_1
From version 02.00.00
Selection of the ramp time for the synchronisation
process to setpoint speed after the brake opening time
has elapsed
Revised behaviour from version 02.00.00:
• 1 ≡ The ramp time of the effective acceleration of the
ramp function generator (
) is used (Lenze
setting).
• 0 ≡ As before, the ramp time set in
Note:
The changeover can be dynamically both via the ramp
parameter and via bit 6.
Bit 7
Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02582 | Holding brake: Setting
Data type: UNSIGNED_8
Index: 21993
d
= 55E9
h
Parameter | Name:
C02589 | Holding brake: Time system
Data type: UNSIGNED_16
Index: 21986
d
= 55E2
h
Operating times of the holding brake
• The electromechanical delay times of the holding brake are specified in the data sheets or on the holding brake
nameplate.
Setting range
(min. value | unit | max. value)
0
ms
60000
Subcodes
Lenze setting
Info
C02589/1
100 ms
Holding brake: Application time
• Time in which the holding brake is completely applied
from the beginning of control and in which the
controller is inhibited.
C02589/2
100 ms
Holding brake: Release time
• Time in which the holding brake is completely
released from the beginning of control.
C02589/3
100 ms
Holding brake: Waiting time status
• Time after which all transient reactions are
completed and the switching status of the holding
brake is stable. Beginning of monitoring the feedback
signal for the switching status of the holding brake.
C02589/4
0 ms
Holding brake: Ramp time FF ctrl
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1