C01231
C01232
C01233
Parameter | Name:
C01231 | MCK: Manual jog speeds
Data type: INTEGER_32
Index: 23344
d
= 5B30
h
Manual jog speeds
Setting range
(min. value | unit | max. value)
-214748.3647
units/s
214748.3647
Subcodes
Lenze setting
Info
C01231/1
360.0000 units/s
Manual jog: speed 1
• Regular manual speed
C01231/2
720.0000 units/s
Manual jog: Speed 2
• Second manual speed (can be activated via MCK
control word)
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C01232 | MCK: Manual jog accelerations
Data type: INTEGER_32
Index: 23343
d
= 5B2F
h
Acceleration/deceleration for manual jog
Setting range
(min. value | unit | max. value)
-214748.3647
units/s2
214748.3647
Subcodes
Lenze setting
Info
C01232/1
720.0000 units/s2
Manual jog: Acceleration
• Acceleration for ramp-up to manual speed.
C01232/2
720.0000 units/s2
Manual jog: Deceleration
• Deceleration for manual speed ramp-down to
standstill.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C01233 | MCK: Manual jog S-ramp time
Data type: UNSIGNED_16
Index: 23342
d
= 5B2E
h
S-ramp time for manual jog
• Setting "0 s" ≡ no rounding
Setting range
(min. value | unit | max. value)
0.000
s
10.000
Subcodes
Lenze setting
Info
C01233/1
0.000 s
Manual jog: S-ramp time
• S-ramp time for the manual speed ramps.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000