2 ta "actuating drive speed, Ta "actuating drive speed, 8technology applications – Lenze 8400 TopLine User Manual
Page 430
8
Technology applications
8.2
TA "Actuating drive speed"
430
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.2
TA "Actuating drive speed"
Features
• Pre-configured control modes for terminals and bus control (with predefined process data
connection to the fieldbus)
• Free configuration of input and output signals
• Offset, gain, and negation of main setpoint, additional setpoint, actual process controller value
• Up to 15 fixed setpoints for speed and ramp time
• Adjustable setpoint ramp times
• Freely selectable, variable ramp shape
• Automatic holding brake control
• Quick stop (QSP) with adjustable ramp time
• Motor potentiometer function
• Process controller
• Load monitoring (in preparation)
• Integrated, freely available "GeneralPurpose" functions:
Analog switch, arithmetic, multiplication/division, binary delay element, binary logic, analog
comparison, D-flipflop
• Interface to the safety module (optional)
• Integration of encoder feedback
Related topics:
Commissioning of the "Actuating drive speed" technology application