C00711 | la_tabpos: digital connection list, C00711/x, C00711 – Lenze 8400 TopLine User Manual
Page 1054: 17 parameter reference
![background image](/manuals/566308/1054/background.png)
17
Parameter reference
17.2
Parameter list | C00711
1054
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00711
C00710/18
0: Not connected
: nGPCompareIn2_a
Input for comparison operation - analog signal 2
C00710/19
0: Not connected
: wGPCounter1LdVal
Input for load value for counter module 1
C00710/20
0: Not connected
: wGPCounter1CmpVal
Input for comparison value for counter module 1
C00710/21
0: Not connected
: nSpeedOverride_a
Input for speed override
C00710/22
0: Not connected
: nAccOverride_a
Input for acceleration override
C00710/23
0: Not connected
: wFreeIn1
Input for user signal 1
C00710/24
0: Not connected
: wFreeIn2
Input for user signal 2
C00710/25
0: Not connected
: wFreeIn3
Input for user signal 3
C00710/26
0: Not connected
: wFreeIn4
Input for user signal 4
C00710/27
0: Not connected
: nPosCtrlOutLimit
Input for correcting variable limitation of position
controller
C00710/28
0: Not connected
: nPosCtrlPAdapt
Input for adapting the position controller gain
C00710/29
0: Not connected
: wSMCtrl
Interface to the optional safety system
C00710/30
0: Not connected
: wPosProfileUnitsLW
Input for selecting the target position in [units], Low-
Word
C00710/31
0: Not connected
: wPosProfileUnitsHW
Input for selecting the target position in [units], High-
Word
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00710 | LA_TabPos: Analog connection list
Data type: UNSIGNED_16
Index: 23865
d
= 5D39
h
Parameter | Name:
C00711 | LA_TabPos: Digital connection list
Data type: UNSIGNED_16
Index: 23864
d
= 5D38
h
Connection parameters for "Table positioning" application: Binary inputs
• Selection of the binary output signals to be connected to the binary input signals
• The selection list contains all binary output signals which can be assigned to the binary inputs mapped by the
subcodes.
Selection list
See
selection list - digital signals
Subcodes
Lenze setting
Info
C00711/1
0: Not connected
: bCInh
Control input for setting controller inhibit
C00711/2
0: Not connected
: bFailReset
Control input for error acknowledgement
C00711/3
0: Not connected
: bSetQuickstop
Control input for quick stop request
C00711/4
0: Not connected
: bSetSpeedCcw
Control input for negation of speed direction