1 terminals 0, Terminals 0, 8technology applications – Lenze 8400 TopLine User Manual
Page 505
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
505
8
Technology applications
8.4
TA "Table positioning"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.4.3.1
Terminals 0
When the profile is defined, the operating mode in the Lenze setting is changed simultaneously:
Connection
Assignment
Connection
Assignment
X101/NC-NO
LA_TabPos.bDriveFail
X5/RFR
LA_TabPos.bFailReset
X3/A1U
LA_TabPos.nMainSetValue_a
10 V ≡ 100 % reference speed (
X5/DI1
-
X3/A1I
X5/DI2
-
X3/A2U
-
X5/DI3
LA_TabPos.bLimitSwitchPos
X3/A2I
-
X5/DI4
LA_TabPos.bLimitSwitchNeg
X3/O1U
LA_TabPos.nMotorSpeedAct_a
10 V ≡ 100 % reference speed (
X5/DI5
LA_TabPos.bPosProfileNo_2
X3/O1I
X5/DI6
LA_TabPos.bPosProfileNo_1
X3/O2U
LA_TabPos.nMotorCurrent_a
10V ≡ 100% of I
max_mot
)
X5/DI7
LA_TabPos.bPosExecute
X3/O2I
X107/BD1
LA_TabPos.bMBrakeReleaseOut
X4/DO1
LA_TabPos.bDriveReady
X107/BD2
-
X4/DO2
LA_TabPos.bInTarget
X4/DO3
LA_TabPos.bHomePosAvailable
bPosProfileNo_2
(DI5)
bPosProfileNo_1
(DI6)
Selected profile
Activation of operating mode
FALSE
FALSE
0
Speed follower
FALSE
TRUE
1
Homing
TRUE
FALSE
2
Manual jog
TRUE
TRUE
3
Positioning
X5
A2I
AR
COM
CG
A1U
NC
CL
A2U
A1I
NO
CH
X107
X4
X3
DI3
DI2
DI4
DI5
DI6
DI7
GI
24I
DI1
RFR
24B
24O
GB
DO1
BD2
DO3
GO
BD1
DO2
GA
O1U
O1I
O2U
O2I
X101
X1
24E
+
+
=
=
+
DriveReady
Load mechanicals
in target position
Home position known
Controller enable
External
supply
24 V DC
pos. direction
neg. direction
Bit 2
Bit 1
Start profile generation
Actual speed value (V)
Actual speed value (I)
Act. mot. current val. (V)
Act. mot. current val. (I)
Speed setpoint
Limit switch
Profile no. 0 ... 3
DriveFail
MBrakeReleaseOut