C01307
C01308
C01309
Parameter | Name:
C01307 | Profile data: Sequence profile
Data type: UNSIGNED_8
Index: 23268
d
= 5AE4
h
Selection of the sequence profile numbers for profiles 1 ... 15
• For profile linkage
Setting range
(min. value | unit | max. value)
0
15
Subcodes
Lenze setting
Info
C01307/1
0
Profiles 1 ... 15: Sequence profile
C01307/...
C01307/15
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01308 | Profile data: TP profile
Data type: UNSIGNED_8
Index: 23267
d
= 5AE3
h
Selection of the touch-probe profile numbers for profile 1 ... 15
• Only relevant for positioning modes with touch-probe.
Setting range
(min. value | unit | max. value)
0
15
Subcodes
Lenze setting
Info
C01308/1
0
Profile 1 ... 15: TP profile
C01308/...
C01308/15
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01309 | Profile data: TP signal source
Data type: UNSIGNED_8
Index: 23266
d
= 5AE2
h
Selection of the touch-probe signal sources for profile 1 ... 15
• Only relevant for positioning modes with touch-probe.
Selection list
3 TP-DigIn3
4 TP-DigIn4
5 TP-DigIn5
6 TP-DigIn6
7 TP-DigIn7
8 TP-Z-trace encoder
9 TP-Z-trace resolver
Subcodes
Lenze setting
Info
C01309/1
3: TP-DigIn3
Profiles 1 ... 15: Sequence profile
C01309/...
C01309/15
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1