72 l_curve_2, 72 l_curve_2 0, L_curve_2 – Lenze 8400 TopLine User Manual
Page 1480: 19 function library
19
Function library
19.1
Function blocks
1480
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
19.1.72
L_Curve_2
This FB can optionally display a characteristic function or a curve function y=f(x), the X axis being
the input signal and the Y axis being the output signal.
• A limitation of the input value can be set in
(upper limit) and
(lower limit).
• The output value is internally limited to ±199.99 %. If a limitation of the output value is active,
bLimit is set to TRUE.
Inputs
Outputs
Parameter
Identifier
Data type
Information/possible settings
nIn_a
INT
Input value (x)
• ±16384 ≡ ±100 %
• A limitation of the input value can be set in C01026/1 (upper limit) and C01026/2
(lower limit).
Identifier
Data type
Value/meaning
nOut_a
INT
Output value (y)
• ±16384 ≡ ±100 %
• Internal limitation to ±32767 (±199.99 %)
bLimit
BOOL
"Limitation active" status signal
TRUE The output value is limited to ±199.99 %.
Parameter
Possible settings
Info
-199.99
%
199.99 Output value
• Read only
Function selection
0 Out = 0
FB deactivated (Lenze setting)
1 Out = In
2 Out = f(In)
In preparation!
3 Out = f(table)
See description of L_Curve_1:
-199.99
%
199.99 Upper limit for input value
• Lenze setting: 199.99 %
-199.99
%
199.99 Lower limit for input value
• Lenze setting: -199.99 %
/B&XUYHB
Q2XWBD
Q,QBD
E/LPLW
& )XQFWLRQ
[
\
[
\
&
&
&[
&[
&
;9DOB
<9DOB