8technology applications – Lenze 8400 TopLine User Manual
Page 503
![background image](/manuals/566308/503/background.png)
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
503
8
Technology applications
8.4
TA "Table positioning"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
GP: GeneralPurpose
The following outputs are interconnected with logic/arithmetic functions on application level for free usage.
nGPAnalogSwitchInOut_a
INT
: Output signal
nGPArithmetikOut_a
INT
: Output signal
nGPMulDivOut_a
INT
: Output signal
bGPDigitalDelayOut
BOOL
: Output signal
bGPLogicOut
BOOL
: Output signal
bGPCompareOut
BOOL
: Output signal
bGPSignalOut1
...
bGPSignalOut4
BOOL
: Output signals
• The signal sources to be output are selected in
.
• A bit coded inversion of the output signals can be parameterised in
nGPSignalOut1_a
...
nGPSignalOut4_a
BOOL
: Output signals
• The signal sources to be output are selected in
.
• Gain and offset for each output signal can be parameterised in
bGPDFlipFlop_Out
BOOL
: Output signal
bGPDFlipFlop_NegOut
BOOL
: Negated output signal
bGPCounter1Equal
BOOL
: Status signal "Comparison value reached"
TRUE Comparison value wGPCounter1CmpVal reached.
wGPCounter1Out
WORD
: Counter content
• Internal limitation to ± 32767
• The most significant bit determines the sign!
Free outputs
The following outputs can freely be interconnected on the application level.
The signals from the application level can be transferred to the I/O level via these outputs.
bFreeOut1 ... bFreeOut8
BOOL
Free outputs for digital signals
wFreeOut1 ... wFreeOut4
WORD
Free outputs for 16-bit signals
dnFreeOut1_p
dnFreeOut2_p
WORD
Free outputs for 32-bit signals
Identifier
Data type
Value/meaning