16 parameter change-over, Parameter change-over – Lenze 8400 TopLine User Manual
Page 859
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
859
16
Parameter change-over
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
16
Parameter change-over
For up to 32 freely selectable parameters, this basic function provides a change-over between four
sets with different parameter values.
The parameter list is created in the same way as the user menu is composed, namely by means of
parameterisation. In the »Engineer«, a user-friendly parameterisation dialog with import and
export functions is available for this purpose.
Motor data changeover
From version 12.00.00
, an optional changeover between four parameter sets with different motor
and control settings is supported in addition.
The optional motor data changeover is provided for applications/machines which have multiple
axes controlled successively but which do not require the simultaneous operation of multiple
motors. In this case, the very same controller can control the motors successively. Advantages of this
solution: Fewer components (controllers) and hence less energy consumption.
[16-1] Principle of the selective control of multiple motors using one controller
Motor data changeover
Motor changeover (e.g. via motor contactors)
Principle:
• The motor which is being controlled at the
moment is connected to the controller via
motor contactors. (The contactor system
can e.g. be controlled via the digital
outputs of the controller.)
• At the same time, the motor data
changeover serves to activate the motor
and control settings suitable for the motor
in the controller.
Note:
The motor data changeover is carried out
within 2 ms and hence within the opening and
closing times of most motor contactors.
M1
3~
M2
3~
M3
3~
M4
3~
Motordata parameterset 1
Motordata parameterset 2
Motordata parameterset 3
Motordata parameterset 4
1
0