2 conventions used for input/output identifiers, Conventions used for input/output identifiers 4, 18 working with the fb editor – Lenze 8400 TopLine User Manual
Page 1334
![background image](/manuals/566308/1334/background.png)
18
Working with the FB Editor
18.1
Basics
1334
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
18.1.2
Conventions used for input/output identifiers
This chapter describes the conventions used for the identifiers of the inputs/outputs of the blocks.
The conventions ensure a uniform and consistent terminology and make reading and
comprehending the interconnection and application easier.
Tip!
The conventions used by Lenze are based on the "Hungarian Notation". This ensures that
the most significant characteristics of the corresponding input/output (e.g. the data type)
can be instantly recognised from its identifier.
An identifier consists of
• a data type entry
• an identifier (the "proper" name of the input/output)
• an (optional) signal type specification
Data type entry
The data type entry provides information about the data type of the corresponding input/output:
Identifier
The identifier is the proper name of the input/output and should indicate the application or
function.
• Identifiers always start with a capital letter.
• If an identifier consists of several "words", then each "word" must start with a capital letter.
• All other letters are written in lower case.
Data type entry
Meaning
Resolution
Value range
b
BOOL
1 bit
0 ≡ FALSE / 1 ≡ TRUE
dn
DINT
32 bits
-2147483647 ... 2147483647
n
INT
16 bits
-32767 ... 32767
w
WORD
16 bits
0 ... 65535