C00070 | vp speed controller, C00071 | ti speed controller, C00072 | sc: tdn speed controller – Lenze 8400 TopLine User Manual
Page 901: C00073 | imax/m controller gain, C00070/1, C00071/1, C00070/2, C00071/2, C00070/3, C00071/4
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
901
17
Parameter reference
17.2
Parameter list | C00070
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00070
C00071
C00072
C00073
Parameter | Name:
C00070 | Vp speed controller
Data type: UNSIGNED_16
Index: 24505
d
= 5FB9
h
Amplification factor Vp of the speed controller for different motor control modes
Setting range
(min. value | unit | max. value)
0.00
600.00
Subcodes
Lenze setting
Info
C00070/1
15.00
: Vp speed controller
C00070/2
6.00
: Vp speed controller
C00070/3
3.00
: Vp speed controller
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00071 | Ti speed controller
Data type: UNSIGNED_16
Index: 24504
d
= 5FB8
h
Reset time Ti of the speed controller for different motor control modes
Setting range
(min. value | unit | max. value)
0.0
ms
6000.0
Subcodes
Lenze setting
Info
C00071/1
100.0 ms
: Ti speed controller
C00071/2
50.0 ms
: Ti speed controller
C00071/3
100.0 ms
: Ti speed controller
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C00072 | SC: Tdn speed controller
Data type: UNSIGNED_16
Index: 24503
d
= 5FB7
h
Differential time constant Tdn of the speed controller for servo control (
) and sensorless control for synchronous
motors (
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
ms
3.00 0.00 ms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00073 | Imax/M controller gain
Data type: UNSIGNED_16
Index: 24502
d
= 5FB6
h
Amplification factor Vp of certain controllers for different motor control modes
Setting range
(min. value | unit | max. value)
0.00
100.00
Subcodes
Lenze setting
Info
C00073/1
0.25
: Vp Imax controller
• After the motor to be used has been selected from the
motor catalogue, the suitable value can be entered
automatically.
C00073/2
1.25
: Vp torque controller
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100