C01110 | ls_multiencoder: solid measure, C01111 | ls_multiencoder: encoder constant, C01112 | ls_multiencoder: position values – Lenze 8400 TopLine User Manual
Page 1164: C01112/1, C01110, C01111/1, C01111/3, Which is, C01112/2, C01112/3
17
Parameter reference
17.2
Parameter list | C01110
1164
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01110
C01111
C01112
Parameter | Name:
C01110 | LS_MultiEncoder: Solid measure
Data type: UNSIGNED_8
Index: 23465
d
= 5BA9
h
From version 02.00.00
Configuration examples can be found in the following chapters:
SinCos absolute value encoder with HIPERFACE® protocol
•
SSI absolute value encoder with Stegmann-SSI protocol
Selection list
(Lenze setting printed in bold)
Info
0 rotatively unipolar
1 linearly unipolar
2 rotatively bipolar
3 linearly bipolar
4 Inverted rotatively in unipolar mode
From version 15.00.00
5 Inverted linearly in unipolar mode
6 Inverted rotatively in bipolar mode
From version 15.00.00
7 Inverted linearly in bipolar mode
From version 15.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01111 | LS_MultiEncoder: Encoder constant
Data type: INTEGER_32
Index: 23464
d
= 5BA8
h
From version 02.00.00
Configuration examples can be found in the following chapters:
SinCos absolute value encoder with HIPERFACE® protocol
•
SSI absolute value encoder with Stegmann-SSI protocol
Setting range
(min. value | unit | max. value)
1
2147483647
Subcodes
Lenze setting
Info
C01111/1
1
: Difference - traverse path
C01111/2
1
: Difference - encoder value
C01111/3
1
: Traverse path - encoder increment
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01112 | LS_MultiEncoder: Position values
Data type: INTEGER_32
Index: 23463
d
= 5BA7
h
Encoder/feedback system: Multi-Encoder
Setting range
(min. value | unit | max. value)
-214748.3647
units
214748.3647
Subcodes
Lenze setting
Info
C01112/1
0.0000 units
: Position offset
C01112/2
-214748.3647 units
: Data area min
C01112/3
214748.3647 units
: Data area max
C01112/4
0.0000 units
: Max. position jump
•
From version 14.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000