1 parameterising the encoder, Parameterising the encoder, 6encoder/feedback system – Lenze 8400 TopLine User Manual
Page 337
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
337
6
Encoder/feedback system
6.3
Multi-Encoder (X8)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.3.3
SSI absolute value encoder with Stegmann-SSI protocol
All SSI encoders which use the Stegmann SSI protocol are supported.
• Supported bit rates for SSI communication: 100 ... 1000 kbits
• Supported data word widths: 1 ... 31 bits (effective)
• Supported output code of the SSI encoder: Gray or binary
• The SSI encoder can be used as position encoder or master encoder with a minimum cycle time
of 1 ms.
• The SSI encoder can be supplied via X8 up to a maximum voltage of 12 V and a maximum
current of 0.25 A.
• The received SSI data words are provided to the application via the
system
block for further processing in the function block editor.
6.3.3.1
Parameterising the encoder
Parameterisation dialog (cutout)
Further parameterisation dialogs:
Note!
For some SSi encoder types it is common that despite a high data transfer rate an slow
position detection (e.g. every 5, 10 or 20 ms) takes place. In this case, the position control,
working in a 1-ms cycle, only functions with low gain and thus low dynamics since the
values of the SSI encoder are only updated every x ms.
When an external SSI laser position encoder is used at X8:
Also observe the
Notes for using an SSI laser position encoder
at the end of this chapter.
Parameter
Info
Lenze setting
Value Unit
LS_MultiEncoder: Encoder type
0: Incremental encoder (TTL)
LS_MultiEncoder: Supply voltage
5.0 V
LS_MultiEncoder: Position offset
0.0000 units