C02256 | ls_writeparamlist: moment of inertia, C02260 | ls_writeparamlist: speed sensor selection, C02256/1 – Lenze 8400 TopLine User Manual
Page 1247: C02256/2, C02256/3, C02256/4, C02260/1, C02260/2, C02260/3, C02260/4
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1247
17
Parameter reference
17.2
Parameter list | C02256
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02256
C02260
C02261
Parameter | Name:
C02256 | LS_WriteParamList: Moment of inertia
Data type: UNSIGNED_32
Index: 22319
d
= 572F
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.00
kg cm^2
6000000.00
Subcodes
Lenze setting
Info
C02256/1
0.00 kg cm^2
: c273_val1
C02256/2
0.00 kg cm^2
: c273_val2
C02256/3
0.00 kg cm^2
: c273_val3
C02256/4
0.00 kg cm^2
: c273_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C02260 | LS_WriteParamList: Speed sensor selection
Data type: UNSIGNED_8
Index: 22315
d
= 572B
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Selection list
0 No sensor
1 Sensor signal FreqIn12
2 Encoder signal FreqIn67
3 Multi encoder
4 Resolver
5 Encoder signal FreqIn1267
Subcodes
Lenze setting
Info
C02260/1
0: No sensor
: c495_val1
C02260/2
0: No sensor
: c495_val2
C02260/3
0: No sensor
: c495_val3
C02260/4
0: No sensor
: c495_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C02261 | LS_WriteParamList: SC: Field feedforward control
Data type: UNSIGNED_16
Index: 22314
d
= 572A
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0
%
600
Subcodes
Lenze setting
Info
C02261/1
200 %
: c576_val1
C02261/2
200 %
: c576_val2
C02261/3
200 %
: c576_val3
C02261/4
200 %
: c576_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1