Oc5: ixt overload [xx.0119.00050, Ot1: maximum torque reached [xx.0123.00001, Oc7: motor overcurrent [xx.0123.00007 – Lenze 8400 TopLine User Manual
Page 708: Oc5: ixt overload, Oc7: motor overcurrent, Ot1: maximum torque reached, Sd12: thermal detector error - multiencoder, Xx.0119.00050, Xx.0123.00007, Xx.0123.00001
10
Diagnostics & error management
10.9
Error messages of the operating system
708
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Sd12: Error thermal detector MultiEncoder [xx.0119.00022]
oC5: Ixt overload [xx.0119.00050]
ot1: Maximum torque reached [xx.0123.00001]
oC7: Motor overcurrent [xx.0123.00007]
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
The signals of the encoder connected to the encoder
interface are outside the defined operating range of the
motor temperature detection.
• Check contacts of the encoder cable at the motor and
controller.
• Check the selected motor temperature sensor in
as to whether it complies with the
assembly in the motor.
• If required, switch off thermal sensor monitoring
(
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
The Ixt overload check has tripped.
• Operating threshold = 100 % Ixt (adjustable in
)
Possible causes:
• Wrong dimensioning of the device with regard to its
motor load.
• Load cycles are not complied with.
• Check and, if required, correct dimensioning of the
device and the motor load with regard to technical
data.
• Reduce motor load cycles (observe load cycles
according to documentation).
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
The device indicates that the maximally possible torque
at the motor shaft has been reached.
•
displays the current torque.
Reduce motor load.
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
Maximum current monitoring has tripped.
• The instantaneous value of the motor current has
exceeded the limit value set in
Check and, if required, correct dimensioning of the load
with regard to the installed device power.