5
Motor control (MCTRL)
5.1
Motor selection/Motor data
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Execute automatic motor parameter identification
How to carry out automatic motor parameter identification:
1. Activate motor parameter identification via the
= "1: On / start" device
command.
2. Enable controller.
• The controller changes to the "
" device status.
• Motor parameter identification starts.
• The progress of the identification run can be seen in
• The identification is completed if the "0: Off / ready" message is displayed in
• After successful identification, it changes back to the "
" device status.
3. Inhibit controller again.
Danger!
During motor parameter identification, the motor is energised via the outputs U, V and
W of the controller!
• Observe the corresponding safety instructions!
• With an idling motor, a small angular offset may occur at the motor shaft.
• During the motor parameter identification, rotations occur in case of a synchronous
motor.