8technology applications – Lenze 8400 TopLine User Manual
Page 514
![background image](/manuals/566308/514/background.png)
8
Technology applications
8.4
TA "Table positioning"
514
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Output words
Name
Assignment
Word 1 DriveControlStatus
Status word
• For bit assignment see the table below.
Word 2 GPSignalOut1
Analog signal monitor: Output signal 1
• The selection of the signal source to output is executed in
.
• Gain and offset for the output signal can be parameterised in
and
.
• For a detailed functional description see
the
FB.
Word 3 and 4 SetPos
Absolute position setpoint in [increments]
• 65535 [Increments] ≡ 1 motor revolution
• The position resolution, i.e. how many increments form one
unit, is displayed in
Word 5 MotorSpeedAct
Actual speed value
• Scaling: 16384 ≡ 100 % reference speed (
)
• Only available in control mode "40: MCI".
Word 6 ... 16 -
Not preconfigured
• Only available in control mode "40: MCI".
Status word
Name
Status
Bit 0 DriveFail
1 ≡ Drive controller in error status
• "
" device status is active.
Bit 1 GPSignalOut1
Binary signal monitor: Output signals 1 & 2
• The signal sources to be output are selected in
• A bit coded inversion of the output signals can be
parameterised in
.
• For a detailed functional description see
FB
.
Bit 2 GPSignalOut2
Bit 3 CInhActive
1 ≡ Controller inhibit is active
Bit 4 DriveReady
1 ≡ Drive controller is ready for operation
• "
" device status is active.
• The drive is in this device status if the DC bus voltage is
applied and the controller is still inhibited by the user
(controller inhibit).
Bit 5 DigitalInput5
Signal from the digital input DI5
Bit 6 DigitalInput6
Signal from the digital input DI6
Bit 7 DigitalInput7
Signal from the digital input DI7
Bit 8 InTarget
1 ≡ Target position (actual value) is in the target window
Bit 9 ProfileBusy
1 ≡ Profile positioning is active
Bit 10 HomePosAvailable
1 ≡ Home position is known
Bit 11 SpeedActCompare
Result of the speed comparison (detection of speed=0)
• In case of the "Open loop" operation:
1 ≡ Speed setpoint < comparison value (
• For "Closed loop" operation:
1 ≡ actual speed value < comparison value (
Bit 12 DigitalInput4
Signal from the digital input DI4
Bit 13 DigitalInput3
Signal from the digital input DI3
Bit 14 QSPIsActive
1 ≡ Quick stop is active
Bit 15 -
Free status bit 15 (not assigned, freely assignable)