6 table of attributes, 6 table of attributes 0, 17 parameter reference – Lenze 8400 TopLine User Manual
Page 1310
![background image](/manuals/566308/1310/background.png)
17
Parameter reference
17.6
Table of attributes
1310
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.6
Table of attributes
The table of attributes contains information required for a communication with the controller via
parameters.
How to read the table of attributes:
Column
Meaning
Entry
Code
Parameter name
Cxxxxx
Name
Parameter short text (display text)
Text
Type
Parameter type
Selection list
Value from selection list
Bit coded
Bit-coded value
Linear value
Value with setting range
String
String of digits
Index
dec
Index under which the parameter is addressed.
The subindex for array variables corresponds to the
Lenze subcode number.
24575 - Lenze code number
Is only required for access via a bus
system.
hex
5FFF
h
- Lenze code number
Data
DS
Data structure
E
Single variable
(only one parameter element)
A
Array variable
(several parameter elements)
DA
Number of array elements (subcodes)
Number
DT
Data type
INTEGER_16
2 bytes with sign
INTEGER_32
4 bytes with sign
UNSIGNED_8
1 byte without sign
UNSIGNED_16
2 bytes without sign
UNSIGNED_32
4 bytes without sign
VISIBLE_STRING [xx]
ASCII string (with character length xx)
Factor
Factor for data transmission via a bus system,
depending on the number of decimal positions
Factor
1 ≡ no decimal positions
10 ≡ 1 decimal position
100 ≡ 2 decimal positions
1000 ≡ 3 decimal positions
10000 ≡ 4 decimal positions
CINH
Writing is only possible if the controller is inhibited CINH
Code
Name
Type
Index
Data
dec
hex
DS
DA
DT
Factor
CINH
Keypad UserLevel
Selection list
24574
5FFE
A
1
UNSIGNED_8
1
Device commands
Selection list
24573
5FFD
A
34
UNSIGNED_8
1
Status of the last device command
Selection list
24572
5FFC
E
1
UNSIGNED_8
1
Application
Selection list
24570
5FFA
E
1
UNSIGNED_16
1
Motor control
Selection list
24569
5FF9
E
1
UNSIGNED_8
1
Control mode
Selection list
24568
5FF8
E
1
UNSIGNED_16
1
Original application|control source
Selection list
24567
5FF7
E
1
UNSIGNED_16
1
AIN1: Characteristic
Linear value
24565
5FF5
A
8
INTEGER_16
100
Appl.: Reference speed
Linear value
24564
5FF4
E
1
UNSIGNED_16
1
Accel. time - main setpoint
Linear value
24563
5FF3
E
1
UNSIGNED_32
1000
Decel. time - main setpoint
Linear value
24562
5FF2
E
1
UNSIGNED_32
1000
VFC: V/f base frequency
Linear value
24560
5FF0
E
1
UNSIGNED_16
10
VFC: Vmin boost
Linear value
24559
5FEF
E
1
UNSIGNED_16
100
Switching frequency
Selection list
24557
5FED
E
1
UNSIGNED_8
1
Auto-DCB: Threshold
Linear value
24556
5FEC
E
1
UNSIGNED_16
1
AIN2: Characteristic
Linear value
24555
5FEB
A
8
INTEGER_16
100
Slip comp.
Linear value
24554
5FEA
E
1
INTEGER_16
100
Imax in motor mode
Linear value
24553
5FE9
E
1
UNSIGNED_16
100
Grayed out = display parameter (read access only)