2 "io" function, Io" function, 14 axis bus – Lenze 8400 TopLine User Manual
Page 855
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
855
14
Axis bus
14.3
IO axis bus
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
14.3.2
"IO" function
With this setting, the IO axis bus is used as a pure IO transmission medium, just like it the case for
the 9300 and 9400 device series.
The "IO" function is activated in
by selecting "3: IO".
• By setting the
.bSetFail_DigOut input to TRUE, the IO axis bus is set to the
dominant level and for all nodes, the
.bFail_DigIn output is set to TRUE.
.bResetFail input has no function.
.bResetFail_In output is always FALSE.
Note!
• "IO" function and
are mutually exclusive since with activated
"IO" function, a synchronisation of the internal time base is not possible (which is
required for a "safe" data transfer).
• The "IO" function must be set for all IO axis bus nodes.
• Triggering an error message with this function is only possible by function block
interconnection.
• Resetting an error message is not possible with this function.