C01093 - ls_parreadwrite 1-6: arithmetic mode, C01094 - ls_parreadwrite 1-6: numerator, 17 parameter reference – Lenze 8400 TopLine User Manual
Page 1161
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1161
17
Parameter reference
17.2
Parameter list | C01093
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01093
C01094
Parameter | Name:
C01093 - LS_ParReadWrite 1-6: Arithmetic mode
Data type: UNSIGNED_8
Index: 23482
d
= 5BBA
h
allows for easy arithmetic conversion of the process value to be written or which
was read into the format of the target parameter via parameterisable factors and without the need for an
additional arithmetic FB.
Selection list
0 No arithmetic
1 In16Bit: LW=+/-32767
2 In16Bit: HW=+/-; LW=0..65535
3 In32Bit: HW_LW=+/-2147483647
Subcodes
Lenze setting
Info
C01093/1
0: no arithmetic
: Arithmetic mode
C01093/2
0: no arithmetic
: Arithmetic mode
C01093/3
0: no arithmetic
: Arithmetic mode
C01093/4
0: no arithmetic
: Arithmetic mode
C01093/5
0: no arithmetic
: Arithmetic mode
C01093/6
0: no arithmetic
: Arithmetic mode
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01094 - LS_ParReadWrite 1-6: Numerator
Data type: INTEGER_16
Index: 23481
d
= 5BB9
h
: Factor (numerator) for internal conversion in arithmetic modes 1 ... 3.
Setting range
(min. value | unit | max. value)
-32767
32767
Subcodes
Lenze setting
Info
C01094/1
1
: Numerator
C01094/2
1
: Numerator
C01094/3
1
: Numerator
C01094/4
1
: Numerator
C01094/5
1
: Numerator
C01094/6
1
: Numerator
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1