19
Function library
19.1
Function blocks
1652
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Required parameter settings
For an error-free function of the sequence control, the following parameter settings are required for
the FB
:
19.1.158.2 Priorities of the control signals
The boolean control signals have the following priorities (1 = highest priority):
1. bReset
2.
bBreak
3.
bPause
4.
bStart
5.
bCancel
Parameter
Info
MCK operating mode at profile no. 0
(
Selection of the operating mode for profile 0 ... 15 at
L_MckCtrlInterface_1.
For these four parameters, set the selection "0: No
change" (no assignment of an operating mode to a
profile).
MCK operating mode at profile no. 1
(
MCK operating mode at profile no. 2
(
MCK operating mode at profile no. 3...15
(
L_MckCtrlInterface_1: Alternative function
(
)
Bit coded selection of the
for the
bit 16 (PosExecute) in the MCK control word.
For this parameter, set the hexadecimal value "0x0" to
deactivate all alternative functions.