C00561 | failure indication, C00565 | resp. to mains phase failure, C00566 | resp. to fan failure – Lenze 8400 TopLine User Manual
Page 1009: C00567 | resp. to speed controller limited, C00565, E logbook and, C00561/3, Stil, Motor phas, C00561/4
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1009
17
Parameter reference
17.2
Parameter list | C00561
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00561
C00565
C00566
C00567
Parameter | Name:
C00561 | Failure indication
Data type: UNSIGNED_8
Index: 24014
d
= 5DCE
h
Failure display of device fans and motor phases
Selection list
0 No error
1 Fault
Subcodes
Info
C00561/1
Internal fan
C00561/2
Heatsink fan
C00561/3
Motor phase U
•
From version 02.00.00
C00561/4
Motor phase V
•
From version 02.00.00
C00561/5
Motor phase W
•
From version 02.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00565 | Resp. to mains phase failure
Data type: UNSIGNED_8
Index: 24010
d
= 5DCA
h
Response to the failure of mains phases
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00566 | Resp. to fan failure
Data type: UNSIGNED_8
Index: 24009
d
= 5DC9
h
Response to the detection of a fan failure
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00567 | Resp. to speed controller limited
Data type: UNSIGNED_8
Index: 24008
d
= 5DC8
h
Response if speed controller output is limited (bLimSpeedCtrlOut = TRUE)
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1