Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
19.1.122.1 Main setpoint path
• The signals in the main setpoint path are limited to a value range of ±32767.
• The signal at nNSet_a is first led via the JOG selection function.
• A selected JOG value switches the nNSet_a input inactive. Then, the subsequent signal
conditioning operates with the JOG value.
19.1.122.2 JOG setpoints
In addition to the direct main setpoint selection via the nNSet_a input, so-called JOG setpoints can
be preset in
.
• The JOG setpoints are binary-coded and can be called using the bJog1 ... bJog8 selection inputs
so that 15 options are available:
• The number of selection inputs to be assigned depends on the number of JOG setpoints
required:
Selection inputs
Main setpoint
Main setpoint
bJog8
bJog4
bJog2
bJog1
FALSE
FALSE
FALSE
FALSE
nNset_a
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
TRUE
TRUE
FALSE
TRUE
FALSE
FALSE
FALSE
TRUE
FALSE
TRUE
FALSE
TRUE
TRUE
FALSE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
TRUE
TRUE
FALSE
TRUE
FALSE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
TRUE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
Number of JOG setpoints required
Number of selection inputs to be assigned (bJog1 ... bJog8)
1
At least 1
2 ... 3
at least 2
4 ... 7
at least 3
8 ... 15
4