C01052 | l_calcdiameter_1: web break monitoring, C01053 | l_processctrl_1: controller times, C01054 | l_processctrl_1: system deviation – Lenze 8400 TopLine User Manual
Page 1147: 17 parameter reference
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1147
17
Parameter reference
17.2
Parameter list | C01052
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01052
C01053
C01054
C01055
Parameter | Name:
C01052 | L_CalcDiameter_1: Web break monitoring
Data type: INTEGER_16
Index: 23523
d
= 5BE3
h
From version 02.00.00
Setting range
(min. value | unit | max. value)
0.00
%
100.00
Subcodes
Lenze setting
Info
C01052/1
10.00 %
: Permissible diameter change
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C01053 | L_ProcessCtrl_1: Controller times
Data type: UNSIGNED_16
Index: 23522
d
= 5BE2
h
From version 02.00.00
Setting range
(min. value | unit | max. value)
0.000
s
30.000
Subcodes
Lenze setting
Info
C01053/1
0.000 s
: Acceleration/deceleration time
C01053/2
0.000 s
: Filter time constant
C01053/3
0.000 s
: Rate time
C01053/4
1.000 s
C01053/5
0.000 s
: Rate action
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C01054 | L_ProcessCtrl_1: System deviation
Data type: INTEGER_16
Index: 23521
d
= 5BE1
h
From version 02.00.00
Setting range
(min. value | unit | max. value)
0.00
%
199.99
Subcodes
Lenze setting
Info
C01054/1
100.00 %
: Gain of system deviation
C01054/2
0.00 %
: Area of system deviation
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C01055 | L_ProcessCtrl_1: Correcting variable limitation
Data type: UNSIGNED_8
Index: 23520
d
= 5BE0
h
From version 02.00.00
Selection list
0 False
1 True
Subcodes
Lenze setting
Info
C01055/1
0: FALSE
: Correcting variable limitation
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1