Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
861
16
Parameter change-over
16.1
Configuring parameter change-over via the »Engineer« parameterisation dialog
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
16.1.1
Configuring the parameter list(s)
Configuring the definable parameter list
In the Lenze setting, the definable parameter list does not yet contain any parameters.
How to configure the definable parameter list:
1. Click the Adapt... button.
• The dialog box entitled Configure WriteParamList is shown:
• On the left-hand side, all the parameters of the drive controller with write and read
access are shown in the list entitled Available parameters.
• If the option In menu groups is activated, all parameters are shown assigned to their
functions.
• By clicking on the
button in the Filter area, you can shorten the list of available
parameters. If, for example, you enter the text "ain1" and then click on the button, only
those parameters whose designation contains this text are shown for selection.
2. Highlight the parameter/parameters in the Available parameters list that is/are to be
added to the WriteParamList.
• Here, you can use the <Ctrl> key and the<Shift> key for multiple selection, as in the case
of general Windows functions.