C00682 | l_compare_1: window, C00685 | l_compare_2: fct, C00686 | l_compare_2: hysteresis – Lenze 8400 TopLine User Manual
Page 1046: C00687 | l_compare_2: window, C00682, 17 parameter reference
17
Parameter reference
17.2
Parameter list | C00682
1046
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00682
C00685
C00686
C00687
Parameter | Name:
C00682 | L_Compare_1: Window
Data type: INTEGER_16
Index: 23893
d
= 5D55
h
FB: Window for the comparison function selected in
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
100.00 2.00 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00685 | L_Compare_2: Fct.
Data type: UNSIGNED_8
Index: 23890
d
= 5D52
h
FB: Comparison operation
• If the statement of the selected comparison operation is true, the binary bOut output will be set to TRUE.
Selection list
(Lenze setting printed in bold)
1 In1 = In2
2 In1 > In2
3 In1 < In2
4 |In1| = |In2|
5 |In1| > |In2|
6 |In1| < |In2|
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00686 | L_Compare_2: Hysteresis
Data type: INTEGER_16
Index: 23889
d
= 5D51
h
FB: Hysteresis for the comparison function selected in
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
100.00 0.50 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00687 | L_Compare_2: Window
Data type: INTEGER_16
Index: 23888
d
= 5D50
h
FB: Window for the comparison function selected in
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
100.00 2.00 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100