C00540
C00545
C00560
Parameter | Name:
C00540 | LS_DFOut: Function
Data type: UNSIGNED_8
Index: 24035
d
= 5DE3
h
From version 12.00.00
Selection of the signal source for the digital frequency output (multi-encoder interface X8)
Selection list
(Lenze setting printed in bold)
1 Off
2 DFIn
3 MotorSpeed
4 LoadSpeed
5 Resolver
6 DigIn 1/2
7 FB input
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00545 | LS_DFOut: Angular offset
Data type: INTEGER_32
Index: 24030
d
= 5DDE
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
0
Incr.
65535
Subcodes
Lenze setting
Info
C00545/1
0 incr.
: Angular offset
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00560 | Fan switching status
Data type: UNSIGNED_8
Index: 24015
d
= 5DCF
h
Display of the function status of the device fans
Selection list
0 Off
1 On
2 No fan
Subcodes
Info
C00560/1
Switching status - internal fan
C00560/2
Switching status - heatsink fan
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1