C01060 | l_posctrllin 1-2: ramps, C01061 | l_posctrllin 1-2: traversing speeds, C01062 | l_switchpoint_1: dead time – Lenze 8400 TopLine User Manual
Page 1149: 17 parameter reference
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1149
17
Parameter reference
17.2
Parameter list | C01060
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01060
C01061
C01062
Parameter | Name:
C01060 | L_PosCtrlLin 1-2: Ramps
Data type: INTEGER_32
Index: 23515
d
= 5BDB
h
From version 02.00.00
Setting range
(min. value | unit | max. value)
0.010
s
130.000
Subcodes
Lenze setting
Info
C01060/1
1.000 s
: Deceleration of set position
C01060/2
1.000 s
: Acceleration ramp
C01060/3
1.000 s
: Deceleration ramp
C01060/4
1.000 s
: Deceleration of set position
C01060/5
1.000 s
: Acceleration ramp
C01060/6
1.000 s
: Deceleration ramp
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C01061 | L_PosCtrlLin 1-2: Traversing speeds
Data type: INTEGER_16
Index: 23514
d
= 5BDA
h
From version 02.00.00
Setting range
(min. value | unit | max. value)
-15000
rpm
15000
Subcodes
Lenze setting
Info
C01061/1
199 rpm
: Forward motion
C01061/2
199 rpm
: Return motion
C01061/3
199 rpm
: Forward motion
C01061/4
199 rpm
: Return motion
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01062 | L_SwitchPoint_1: Dead time
Data type: UNSIGNED_16
Index: 23513
d
= 5BD9
h
From version 02.00.00
Setting range
(min. value | unit | max. value)
0
65535
Subcodes
Lenze setting
Info
C01062/1
0
: Dead time 1
C01062/2
0
: Dead time 2
C01062/3
0
: Dead time 3
C01062/4
0
: Dead time 4
C01062/5
0
: Dead time 5
C01062/6
0
: Dead time 6
C01062/7
0
: Dead time 7
C01062/8
0
: Dead time 8
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1