Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
623
9
Basic drive functions (MCK)
9.6
Homing
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.6.3
Execute homing
Control is exercised by means of bits 8 ... 10 in the
If the Motion Control Kernel is downstream from the MCKInterface in the circuit, the
FB provides the following process inputs for controlling the operating mode:
Homing
MCK control word
Bit 10
Bit 9
Bit 8
HomResetPos
HomSetPos
HomStartStop
Stop homing
0
0
0
Start homing
0
0
1
Set home position
0
1
X
Delete home position
1
0
X
X = Status not significant
Identifier
Data type
Information/possible settings
bHomingStartStop
BOOL
Start/stop homing
• Only possible in the "referencing" operating mode.
TRUE If one of homing modes "4" ... "15" in
is selected:
Start reference search
• The current status of the reference search is indicated via the
status outputs bHomingDone and bHomePosAvailable.
• If the 100_ Set_Ref_directly" referencing mode has been selected
in
, the home position can be set manually via the
bHomeStartStop input with the drive at a standstill. The current
actual position is set as the home position (
)
If homing mode "100: SetRef" is selected:
Setting the home position manually
• The home position is set manually with the drive at a standstill.
The current actual position now corresponds to the reference
position set in
in the machine measuring system.
TRUEFALSE Stop homing.
• If the bHomingStartStop input is reset to FALSE during active
referencing, homing is cancelled and the drive is brought to a
standstill.
bHomingSetPos
BOOL
Set home position (
)
• With referencing "on the fly", the home position of a machine can be set during
ongoing movement. Jerking and compensating movements do not occur.
FALSETRUE The position applied at the dnMotorRefOffset_p input of the
SB
at the time of activation is set as home
position if
= "0: No TP" is set.
bHomingResetPos
BOOL
Delete home position
Note: With this function, positions are not deleted but only the status signals
bHomePosAvailable and bHomePosDone are reset. Setpoints and actual positions
remain untouched until a renewed reference setting or homing.
FALSETRUE The internal status "reference known" is reset.
• The controller is no longer referenced.
• The process outputs bHomePosAvailable and bHomingDone are
reset to FALSE.