Parameter list | C01446
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01446
C01447
C01448
Parameter | Name:
C01446 | L_Sequencer_1: ZählerVergleichswert
Data type: INTEGER_32
Index: 23129
d
= 5A59
h
From version 12.00.00
L_Sequencer_1: "Counting" action
Setting range
(min. value | unit | max. value)
-2147483647
2147483647
Subcodes
Lenze setting
Info
C01446/1
0
: Count. act. 1: comparison value
C01446/...
...
C01446/8
: Count. act. 8: comparison value
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01447 | L_Sequencer_1: ZählerSprungziel
Data type: UNSIGNED_16
Index: 23128
d
= 5A58
h
From version 12.00.00
L_Sequencer_1: "Counting" action
Setting range
(min. value | unit | max. value)
0
100
Subcodes
Lenze setting
Info
C01447/1
0
: Count. act. 1: Jump destination
C01447/...
...
C01447/8
: Count. act. 8: Jump destination
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01448 | L_Sequencer_1: ZählerVergleichsfunktion
Data type: UNSIGNED_16
Index: 23127
d
= 5A57
h
From version 12.00.00
L_Sequencer_1: "Counting" action
Selection list
1 Counter content = comparison value
2 Counter content > comparison value
3 Counter content >= comparison
value
4 Counter content < comparison value
5 Counter content <= comparison
value
Subcodes
Lenze setting
Info
C01448/1
1: Counter content = comparison
value
: Count. act. 1: Comparison op.
C01448/...
...
C01448/8
: Count. act. 8: Comaprison op.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1