3 defining current and speed limits, Defining current and speed limits, 5motor control (mctrl) – Lenze 8400 TopLine User Manual
Page 154
5
Motor control (MCTRL)
5.3
Defining current and speed limits
154
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.3
Defining current and speed limits
Limitation of the speed setpoint
Parameterising the reference speed in
means that the drive must rotate at the set speed if
a speed setpoint of 100% is specified.
All speed setpoint selections are provided in % and always refer to the reference speed set in
.
Tip!
For reasons of achievable resolution and the accuracy involved, the reference speed should
be geared to the speed range required for the respective application.
Lenze recommendation: Reference speed (
) = 1500 ... 3000 rpm
Irrespective of the selected motor control, there are more limitation options:
Parameter
Info
Lenze setting
Value Unit
Max. positive speed
120 %
Max. negative speed
120 %
Max. positive output frequency
1000 Hz
Max. negative output frequency
1000 Hz
Note!
In the torque-controlled operation (bTorquemodeOn = TRUE), the limitation of the speed
setpoint set in
has no impact!
For the torque-controlled operation, a permissible speed range can be defined via the
speed limitation (inputs nSpeedHighLimit_a and nSpeedLowLimit_a at the
SB
For a correct function of the speed limitation in both direction, the following applies:
The speed limitation operates with a internal hysteresis of 50 min
-1
. The upper or lower
speed limit resulting from the settings has to be higher than this hysteresis!