9basic drive functions (mck) – Lenze 8400 TopLine User Manual
Page 611
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
611
9
Basic drive functions (MCK)
9.6
Homing
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Abbreviations used for the referencing modes:
Mode 4: >_Rp_<_TP
(from version 14.00.00)
Process of case 1 Axis has not yet reached the pre-stop mark (bHomingMark = FALSE):
1. Movement in positive direction with start profile data set.
2. Reversing in case of positive edge at bHomingMark and, at the same time, activating the search
profile data set for continued reference searching.
3. Negative edge at bHomingMark enables home position detection.
4. Following edge of the touch probe sensor sets home position.
Process of case 2 Axis is already on the pre-stop mark (bHomingMark = TRUE):
1. Movement in negative direction with search profile data set.
2. Negative edge at bHomingMark enables home position detection.
3. Following edge of the touch probe sensor sets home position.
Abbreviation Meaning
>
Movement in positive direction
<
Movement in negative direction
Lp
Positive travel range limit switch
Ln
Negative travel range limit switch
Rp
Positive edge pre-stop mark/pre-stop signal
Rn
Negative edge - pre-stop mark/pre-stop signal
TP
Touch probe or sensor reference signal/reference switch detected
Mlim
Torque limit value reached
Touch probe
Pre-stop mark
Mode 4
>
Rp
<
TP
Offset path
Sequence profile (optional)
Start speed
Search speed
Profile speed
Lp
Active
Active
Active
Active
Active
Active
Ln
Inactive
Active
Active
Active
Active
Active
1
2
0
1