12 system bus "can on board – Lenze 8400 TopLine User Manual
Page 779
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
779
12
System bus "CAN on board"
12.8
Process data transfer
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
OPTIONAL: Set identifier individually
When "2: COBID = C0354/x" in
, the identifiers for the PDOs can be individually set via the
Lenze codes and CANopen indexes listed in the table below. That way, identifiers independent of
the node address can be set for specific PDOs.
• If identifiers are assigned individually, all PDOs must have basic identifier values in the range of
385 ... 1407.
Object
Lenze code
CANopen index
Default setting
PDO1
TPDO1
COB-ID =
0x201
RPDO1
0x181
PDO2
TPDO2
0x301
RPDO2
0x281
PDO3
TPDO3
0x401
RPDO3
0x381
PDO4
TPDO4
0x501
RPDO4
0x481
Note!
After a node address change (
) and a CAN reset node afterwards, the subcodes of
automatically resume the values which result from the respective basic
identifier and the set node address.