Page 1156: C01081 | l_dfrfg_1: sync. direction / tp function, 17 parameter reference
17
Parameter reference
17.2
Parameter list | C01078
1156
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01078
C01079
C01080
C01081
Parameter | Name:
C01078 | L_DFRFG_1: Following error
Data type: UNSIGNED_32
Index: 23497
d
= 5BC9
h
From version 02.00.00
Setting range
(min. value | unit | max. value)
10
Incr.
2000000000
Subcodes
Lenze setting
Info
C01078/1
2000000000 incr.
: Following error limit
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01079 | L_DFRFG_1: Synchronisation window
Data type: UNSIGNED_16
Index: 23496
d
= 5BC8
h
From version 02.00.00
Setting range
(min. value | unit | max. value)
0
Incr.
65535
Subcodes
Lenze setting
Info
C01079/1
100 incr.
: Synchronisation window (position)
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01080 | L_DFRFG_1: Offset
Data type: INTEGER_32
Index: 23495
d
= 5BC7
h
From version 02.00.00
Setting range
(min. value | unit | max. value)
-2147483647
Incr.
2147483647
Subcodes
Lenze setting
Info
C01080/1
0 incr.
: Offset
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01081 | L_DFRFG_1: Sync. direction / TP function
Data type: UNSIGNED_8
Index: 23494
d
= 5BC6
h
From version 02.00.00
Selection list
1 cw/ccw - without TP
2 cw - without TP
3 ccw - without TP
4 cw/ccw - with TP
5 cw - with TP
6 ccw - with TP
Subcodes
Lenze setting
Info
C01081/1
1: cw/ccw - without TP
: Sync. direction / TP function
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1