9basic drive functions (mck) – Lenze 8400 TopLine User Manual
Page 620
9
Basic drive functions (MCK)
9.6
Homing
620
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Mode 15: <_Mlim
Procedure:
1. Movement in a negative direction with reduced torque and start profile data set.
2. The reference is set if it is detected that the torque limit set in
is exceeded beyond the
time set in
• If a home value offset has not been set, this position is the home position.
• If a home value offset has been set, correctly signed traversing by this offset takes place and
the home position is set at the end of this travel distance.
Tip!
Set a home value offset in
to avoid stopping at the positive stop.
Mode 100: SetRef
When the drive is at standstill, the measuring system is set via the bit 9 ("HomSetPos") in
. The current actual position now corresponds to the home position set in
the machine measuring system.
Mode 15
<
Mlim
Offset path
Sequence profile (optional)
Start speed
Profile speed
Lp
Inactive
Inactive
Active
Active
Ln
Active
Active
Active
Active
Mode 100
SetRef
Offset path
Sequence profile (optional)
-
Start speed
Profile speed
Lp
Active
Active
Active
Ln
Active
Active
Active
1
1