C00821 | l_digitallogic_1: truth table, C00822 | l_digitallogic_2: function, C00821/1 – Lenze 8400 TopLine User Manual
Page 1071: C00821, C00821/8, Is used, 17 parameter reference
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1071
17
Parameter reference
17.2
Parameter list | C00821
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00821
C00822
Parameter | Name:
C00821 | L_DigitalLogic_1: Truth table
Data type: UNSIGNED_8
Index: 23754
d
= 5CCA
h
FB: Parameterisation of the truth table
Selection list
0 False
1 True
Subcodes
Lenze setting
Info
C00821/1
0: FALSE
: bIn3...bIn1=0 0 0
C00821/2
0: FALSE
: bIn3...bIn1=0 0 1
C00821/3
0: FALSE
: bIn3...bIn1=0 1 0
C00821/4
0: FALSE
: bIn3...bIn1=0 1 1
C00821/5
0: FALSE
: bIn3...bIn1=1 0 0
C00821/6
0: FALSE
: bIn3...bIn1=1 0 1
C00821/7
0: FALSE
: bIn3...bIn1=1 1 0
C00821/8
0: FALSE
: bIn3...bIn1=1 1 1
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00822 | L_DigitalLogic_2: Function
Data type: UNSIGNED_8
Index: 23753
d
= 5CC9
h
FB: Selection of the internal logic function
Selection list
(Lenze setting printed in bold)
Info
0 bOut = 0
Constant value "FALSE"
1 bOut = 1
Constant value "TRUE"
2 bOut = bIn1 AND ... bIn3
AND operation
3 bOut = bIn1 OR ... bIn3
OR operation
4 bOut = f (truth table)
The truth table parameterised in
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1