C00181 | time settings, C00182 | l_nset_1: s-ramp time pt1, C00184 | autofailreset repetition time – Lenze 8400 TopLine User Manual
Page 933: C00185 | autofailreset remaining time, C00186 | max. number of autofailreset processes, C00181/1, C00182, C00184, C00185, C00186
![background image](/manuals/566308/933/background.png)
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
933
17
Parameter reference
17.2
Parameter list | C00181
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00181
C00182
C00184
C00185
C00186
Parameter | Name:
C00181 | Time settings
Data type: UNSIGNED_16
Index: 24394
d
= 5F4A
h
Time for device search function (optical location)
Setting range
(min. value | unit | max. value)
0
s
6000
Subcodes
Lenze setting
Info
C00181/1
5 s
Time - device search function
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00182 | L_NSet_1: S-ramp time PT1
Data type: INTEGER_16
Index: 24393
d
= 5F49
h
FB
: PT1 S-ramp time for the main setpoint ramp function generator
• Only effective with activated ramp rounding (
= "1").
Setting range
(min. value | unit | max. value)
Lenze setting
0.01
s
50.00 20.00 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00184 | AutoFailReset repetition time
Data type: UNSIGNED_16
Index: 24391
d
= 5F47
h
After the time set here has expired, an error message of an error that has occurred will be reset automatically if
"AutoFailReset" had been configured correspondingly in
Setting range
(min. value | unit | max. value)
Lenze setting
1
s
600 3 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00185 | AutoFailReset remaining time
Data type: UNSIGNED_16
Index: 24390
d
= 5F46
h
Display of the residual runtime of the "AutoFailReset" function
Display range
(min. value | unit | max. value)
0
s
600
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00186 | Max. number of AutoFailReset processes
Data type: UNSIGNED_8
Index: 24389
d
= 5F45
h
Maximum number of "AutoFailReset" procedures
Setting range
(min. value | unit | max. value)
Lenze setting
1
16 4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1