LS_ParReadWrite 1-6: Denominator
Linear value
23480
5BB8
A
6
INTEGER_16
1
Function L_Counter 1-3
Selection list
23475
5BB3
A
3
UNSIGNED_8
1
Comparison L_Counter 1-3
Selection list
23474
5BB2
A
3
UNSIGNED_8
1
L_SwitchPoint_1: Deadtime factor
Selection list
23467
5BAB
A
8
UNSIGNED_8
1
L_SwitchPointPar_1: Deadtime factor
Selection list
23466
5BAA
A
8
UNSIGNED_8
1
LS_MultiEncoder: Solid measure
Selection list
23465
5BA9
E
1
UNSIGNED_8
1
LS_MultiEncoder: Encoder constant
Linear value
23464
5BA8
A
3
INTEGER_32
1
LS_MultiEncoder: Position values
Linear value
23463
5BA7
A
4
INTEGER_32
10000
LS_MultiEncoder: Current position
Linear value
23456
5BA0
A
2
INTEGER_32
10000
Sync signal source
Selection list
23455
5B9F
E
1
UNSIGNED_8
1
Sync cycle time setpoint
Linear value
23454
5B9E
E
1
UNSIGNED_16
1
Sync phase position
Linear value
23453
5B9D
E
1
UNSIGNED_16
1
Sync window
Linear value
23452
5B9C
E
1
UNSIGNED_16
1
Sync correction width
Selection list
23451
5B9B
E
1
UNSIGNED_8
1
LS_RetainData: Selection
Bit coded
23445
5B95
A
4
UNSIGNED_16
1
LS_RetainData: 16Bit data
Linear value
23444
5B94
A
4
UNSIGNED_16
1
LS_RetainData: 32Bit data
Linear value
23443
5B93
A
4
INTEGER_32
1
LS_RetainData: Bool data
Selection list
23442
5B92
A
4
UNSIGNED_8
1
L_Transient 1-4: Function
Selection list
23437
5B8D
A
4
UNSIGNED_8
1
L_Transient 1-4: Pulse duration
Linear value
23436
5B8C
A
4
UNSIGNED_16
1000
L_Transient 5-8: Function
Selection list
23435
5B8B
A
4
UNSIGNED_8
1
L_Transient 5-8 pulse duration
Linear value
23434
5B8A
A
4
UNSIGNED_16
1000
L_PhaseIntK: Function
Selection list
23425
5B81
A
2
UNSIGNED_8
1
L_PhaseIntK: Compare
Linear value
23424
5B80
A
2
INTEGER_32
1
L_SwitchPointPar_1: Dead time
Linear value
23423
5B7F
A
8
UNSIGNED_16
1
L_SwitchPointPar_1: Hysteresis
Linear value
23422
5B7E
A
8
UNSIGNED_16
1
L_SwitchPointPar_1: CenterMode
Selection list
23421
5B7D
A
8
UNSIGNED_8
1
L_SwitchPointPar_1: Running time
Linear value
23420
5B7C
A
8
UNSIGNED_16
1
L_SwitchPointPar_1: Status
Selection list
23419
5B7B
A
8
INTEGER_16
1
L_SwitchPointPar_1:Position
Linear value
23418
5B7A
A
16
INTEGER_32
10000
L_SwitchPointPar_1: Invert
Bit coded
23417
5B79
A
1
UNSIGNED_16
1
Motor thermal sensor
Selection list
23385
5B59
A
2
UNSIGNED_8
1
PTC characteristic: Temperature 1/2
Linear value
23384
5B58
A
2
UNSIGNED_8
1
PTC characteristic: Resistance 1/2
Linear value
23383
5B57
A
2
INTEGER_32
1
Motor temp. feedback system
Selection list
23382
5B56
E
1
UNSIGNED_8
1
MCK: Cycle
Linear value
23374
5B4E
A
1
INTEGER_32
10000
MCK: iM motor/process
Linear value
23373
5B4D
A
2
UNSIGNED_16
1
MCK: iG motor/position encoder
Linear value
23372
5B4C
A
2
UNSIGNED_16
1
MCK: Feed constant
Linear value
23371
5B4B
E
1
INTEGER_32
10000
MCK: Position resolution
Linear value
23370
5B4A
E
1
INTEGER_32
10000
MCK: Mounting direction
Selection list
23369
5B49
A
2
UNSIGNED_8
1 CINH
MCK: Current positions
Linear value
23365
5B45
A
9
INTEGER_32
10000
MCK: Speed
Linear value
23364
5B44
A
3
INTEGER_32
10000
MCK: Max. traversing distance
Linear value
23362
5B42
A
1
INTEGER_32
1
MCK: Following error
Linear value
23360
5B40
A
3
INTEGER_32
10000
MCK: Positioning setting
Bit coded
23359
5B3F
E
1
UNSIGNED_8
1
MCK: Position follower setting
Bit coded
23357
5B3D
E
1
UNSIGNED_8
1
MCK: Speed follower setting
Bit coded
23356
5B3C
E
1
UNSIGNED_8
1
MCK: Ref. setting
Bit coded
23355
5B3B
A
1
UNSIGNED_16
1
MCK: Homing mode
Selection list
23354
5B3A
E
1
UNSIGNED_8
1
Code
Name
Type
Index
Data
dec
hex
DS
DA
DT
Factor