C01246 | mck: select signal source, C01247 | mck: diagnostic word, C01246/1 – Lenze 8400 TopLine User Manual
Page 1194: C01246/2, 17 parameter reference
17
Parameter reference
17.2
Parameter list | C01246
1194
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01246
C01247
Parameter | Name:
C01246 | MCK: Select signal source
Data type: UNSIGNED_8
Index: 23329
d
= 5B21
h
Selection of the touch probe signal source for reference search with touch probe detection
• If the reference signal is to follow a real touch probe, the
must be configured accordingly.
Selection list
Info
0 No TP
3 TP-DigIn3
4 TP-DigIn4
5 TP-DigIn5
6 TP-DigIn6
7 TP-DigIn7
8 TP-Z-trace encoder
From version 12.00.00
9 TP-Z-trace resolver
From version 12.00.00
Subcodes
Lenze setting
Info
C01246/1
0: No TP
MCK: Ref. TP signal source
Note:
In case of setting "0: No TP", the digital input DI3 is used
as signal source for reference search. An inversion of DI3
via
is considered.
C01246/2
0: No TP
MCK: Set.Ref. signal source
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01247 | MCK: Diagnostic word
Data type: UNSIGNED_32
Index: 23328
d
= 5B20
h
From version 15.00.00
Display area
(min. hex value | max. hex value)
0x00000000
0xFFFFFFFF
Value is bit-coded:
Info
Bit 0 Traversing range: Limited
1 ≡ The traversing range is limited:
• The software limit positions are set.
• The reference is known.
• There is no modulo measuring system available
(
= 0).
Note:
This status does not consider whether the software limit
positions are activated or deactivated by the settings in
the prevailing operating mode.
Bit 1 Traversing range: Modulo
1 ≡ A modulo measuring system is available as a cycle
length has been set in
Bit 2
Reserved
Bit 3
Reserved
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Bit 8 SpeedNormConstant: Low-Limit
1 ≡ Due to the set machine parameters, an internal
calculation constant is limited to a possible minimum.
Remedy: Increase reference speed in
.